750 Va Ups Dbl Cnvrsn Smrtonln 6out USB/Rs-232/Db9/Snmp - 750 / Mfr. No.: Su750rtxl2u

750 Va Ups Dbl Cnvrsn Smrtonln 6out USB/Rs-232/Db9/Snmp - 750 / Mfr. No.: Su750rtxl2u
$440.95
IN STOCK
Qty. Available: 10+
Item Number: tri-su750rtxl2u
Vendor Number: SU750RTXL2U
Vendor: Tripp Lite
Note: Shipping charges are not subsidized on this item.
Chat with or call a Mac expert at 1-888-769-76291-888-769-7629
Shipping: Usually ships within 24 hours.

  • On-line, double-conversion, sine wave UPS with PDU switching, current monitoring and fault-tolerant auto-bypass
  • Tripp Lite's PowerAlert Software, version 12, has tested compatible with Cisco CallManager, versions 3.3(4)-MCS and 4.0(2)-MCS.
  • 750VA on-line, double-conversion, extended-run 2U rack/tower UPS
  • Maintains sine wave 100/110 or 120V +/-2% output during overvoltages to 138V and brownouts as low as 65V (50/60Hz auto-sensing)
  • Simultaneous use communications via HID-compliant USB port, serial port, SNMP/Web card slot and EPO interface
  • Fault-tolerant auto-bypass mode, current monitoring and switched PDU control via 2 switchable output load banks
  • Input NEMA 5-15P (120V 15A); Output 6 NEMA 5-15R (120V)
  • 2-year product warranty and $250,000 Ultimate Lifetime Insurance (USA & Canada only)

750VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 in. Expandable battery runtime with optional BP24V28-2U and BP24V70-3U external battery packs.

Full-time sine wave 100, 110 or 120V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V / NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux.

Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.

KEY BUYING POINTS

SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard-to-solve power problems not addressed by other UPS types

Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 100/110/120V (+/-2%) values
Standard internal battery set offers 11 min. runtime at half load (300W) and 6 min. at full load (600W)

Optional BP24V28-2U and BP24V70-3U external battery pack accessories available

Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 13.5 inches

Ships with all mounting accessories for 4-post rackmount installation

Optional 2POSTRMKITWM enables 2-post rackmount or wallmount installation

Optional 2-9USTAND accessory enables small-footprint upright tower placement

Fault-tolerant auto-bypass maintains continuous utility output to connected equipment, even if the UPS suffers internal failure and requires maintenance

Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot

HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux.

Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints

Built-in Emergency Power Off (EPO) interface with cable

NEMA 5-15P input plug / NEMA 5-15R output receptacles

Integrated 2-bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices (each load bank consists of a single outlet)

Front panel LEDs offer current monitoring and battery charge level information

UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required

Supports 2-post rackmount installation with optional 2POSTRMKITWM accessory

Single-line tel/DSL or network Ethernet line surge suppression

TYPICAL APPLICATIONS

Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.

OPTIONS & ACCESSORIES

  • External battery pack: BP24V28-2U , BP24V70-3U
  • SNMP accessories: SNMPWEBCARD ,ENVIROSENSE
  • Dataline protectors: DNET1 ,DTEL2 ,DCATV
  • Circuit Tester: CT120
  • Rack enclosures: SRNET45UB ,SR45U ,SRX24UB
  • Power distribution: PDU1215 ,PS7224
  • Two Post Rackmount Kit: Tower Stands: 2-9USTAND
  • Extended warranties: 3 Year WEXT3-500-1500, 5 Year WEXT5-500-1500

PACKAGE INCLUDES

  • Online Double-Conversion UPS System
  • PowerAlert Software and cabling
  • Mounting hardware for 4-post rack enclosures
  • Instruction manual with warranty information

 

General Information

ManufacturerTripp Lite
Manufacturer Part NumberSU750RTXL2U
Manufacturer Website Addresshttp://www.tripplite.com
Product LineSmartOnline
Product NameSmartOnline Expandable 750VA Tower/Rack Mountable UPS System
Product TypeDual Conversion Online UPS

Technical Information

Plug/Connector TypeNEMA 5-15P
Receptacles6 x NEMA 5-15R
Dataline ProtectionRJ-45
Bypass SwitchAutomatic
Emergency Power OFFYes
Switching Time0 ns

Power Description

Load Capacity (VA)750 VA
Load Capacity (Watt)600 W
Input Voltage110 V AC
Output Voltage120 V AC

Management

Network ManagementSNMP Manageable

Interfaces/Ports

Serial PortYes
USBYes

Battery Information

Backup/Run Time (Full Load)4 Minute
Backup/Run Time (Half Load)11 Minute
Maximum Battery Recharge Time6 Hour
Hot SwappableYes

Physical Characteristics

Rack Height2U
Form FactorTower/Rack Mountable

Miscellaneous

Package Contents
  • SmartOnline Expandable 750VA Tower/Rack Mountable UPS System
  • Online Double-Conversion UPS System
  • PowerAlert Software and cabling
  • Mounting hardware for 4-post rack enclosures
  • Instruction manual with warranty information
Additional Information
  • Switches: Includes power off/on switch to enable system turn on (press on switch), UPS battery test (press on switch during normal AC operation), buzzer silence (press on switch during battery operation) and off (press off switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds
  • Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 65V (80V at load levels over 70%). Below this switchover point, output is supported from battery-derived AC power
  • High voltage transfer to battery power: Maintains continuous operation without using battery power during overvoltages to 138V. Above this point, output is supported from battery-derived AC power
  • Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Certifications & StandardsTested to UL1778 (USA), CSA (Canada), Class B (EMI)
Software IncludedPowerAlert Software

Warranty